Electrochemical Determination of Diclofenac by Using ZIF-67/g-C3N4 Modified Electrode

Hoa, Dang Thi Ngoc and Tu, Nguyen Thi Thanh and Son, Le Van Thanh and Son, Le Vu Truong and Toan, Tran Thanh Tam and Thong, Pham Le Minh and Nhiem, Dao Ngoc and Lieu, Pham Khac and Khieu, Dinh Quang and Le, Thanh Son (2021) Electrochemical Determination of Diclofenac by Using ZIF-67/g-C3N4 Modified Electrode. Adsorption Science & Technology, 2021. pp. 1-14. ISSN 0263-6174

[thumbnail of 7896286.pdf] Text
7896286.pdf - Published Version

Download (3MB)

Abstract

A facial differential pulse voltammetric procedure using a glassy carbon electrode modified with zeolite imidazolate framework-67/graphitic carbon nitride (ZIF-67/g-C3N4) for the diclofenac (DCF) determination is demonstrated. ZIF-67/g-C3N4 with different mass ratios of the components was synthesized in a self-assembly process. The obtained materials were characterized by using X-ray diffraction, scanning electron microscopy (SEM), EDX-mapping, and nitrogen adsorption/desorption isotherms. The peak current varies linearly with the DCF concentration in the range of 0.2–2.2 μmol·L−1 and has a detection limit of 0.071 μmol·L−1. The modified electrode exhibits acceptable repeatability, reproducibility, and selectivity towards DCF. The proposed electrode allows determining DCF in human urine without pretreatment, and the results are comparable with those determined with HPLC.