Kumar, S. Ashutosh and Debnath, Manidipa and Rao, J.V.L.N. Seshagiri and Sankar, D. Gowri (2015) New Validated Stability-Indicating Rp-HPLC Method for Simultaneous Estimation of Atorvastatin and Ezetimibe in Human Plasma by Using PDA Detector. Advanced Pharmaceutical Bulletin, 5 (3). pp. 385-391. ISSN 2228-5881
APB-5-385.pdf - Published Version
Download (631kB)
Abstract
Purpose: This paper describes a simple, precise and accurate RP-HPLC method for simultaneous estimation of atorvastatin and ezetimibe in plasma.
Methods: The chromatographic separation of the drugs were performed on an X-Terra C8 (4.6 x 150 mm, 3.5 mm), with phosphate buffer [pH 3.5 with Ortho Phosphoric Acid] – acetonitrile 40:60 (v/v) as mobile phase. The detection was performed at 235 nm. The flow rate was maintained at 1.2 mL/min. The run time was 8.0 min.
Results: The accuracy and reliability of the method was assessed by evaluation of linearity (5-25 µg/mL for both atorvastatin calcium and ezetimibe), precision (intra-day RSD 0.57 % and inter-day RSD 0.02 % for atorvastatin calcium and intra-day RSD 0.56 % and inter-day RSD 0.1 % for ezetimibe), accuracy (100.08- 100.84 % for atorvastatin calcium and 100.56- 101.00 % for ezetimibe), and specificity, in accordance with ICH guidelines. The LLOQ obtained by the proposed method were 1.294 and 1.384 µg/mL for atorvastatin and ezetimibe respectively.
Conclusion: Overall the proposed method was found to be suitable and accurate for the quantitative determination in plasma. The method was effectively separated the drug from plasma.