Organic Rankine Cycle Based Geothermal Energy for Power Generation in Egypt ()
1. Introduction
Renewable energy demand is increasing according to the shortage of non-renewable energy resources and their environmental problems. Therefore, electricity generation from the renewable energy sources has a vital importance since it serves as an optimal solution for energy and environmental issues. The biomass, solar, wind, geothermal and oceanic energy are used to tackle the energy crisis. The geothermal energy is a clean, continuous sustainable energy resource and the amount of energy [1] [2] . The low to medium temperature sources are used for thermal heating not in electrical energy generation. In order to generate electricity from low to medium geothermal temperature sources and to increase the utilization of thermal resources by recovering waste heat, binary technologies have been developed [3] . Over the world, the installed capacity of geothermal energy is divided into 48,493 MWt thermal and 117,740 GWh electrical in different 78 countries; the top countries are China, USA, Sweden, Turkey and Japan. Currently, the geothermal binary power plants installed is about 800 MWe, representing 8% of the total geothermal power. The binary power plants are widely used types of geothermal power plant with 193 units in 17 countries [4] . Nowadays, the most common technology for utilizing low temperature geothermal sources for electricity generation is binary cycle power plants. Binary plants are usually constructed in small integrated units of a few hundred kWe to a few MWe capacities [5] . Generally, there are two main types of a binary cycle which are the Organic Rankine Cycle (ORC) and the Kalina cycle. The ORC commonly uses hydrocarbons as the appropriate working fluid and Kalina uses water ammonia mixture [6] [7] . The ORC plant is more economical for geothermal fluid temperature below 180˚C [3] . The main purpose of this work is to generate a power from low temperature geothermal resources using an ORC plant and compare the output power and efficiency for different working fluids. Also, sensitivity analysis of the output generated power to the variation of geothermal temperature, reinjection temperature and geothermal flow rate is performed.
2. Geothermal Energy in Egypt
Nowadays, it is required to increase the use of renewable energy in Egypt up to 20% by 2020. Wind and solar energy are used recently. Geothermal energy till now not used for electricity production, the direct used is recently utilized. North eastern corner of African continent may possess geothermal resources. The Gulf of Suez is characterized with hot spring with different temperature. So, it is the most promising area of geothermal in Egypt. A number of geo-thermometric studies are enhanced for the geothermal water in Egypt. the previous research articles pointed out that Hammam Faraun area attains the highest recorded subsurface formation temperature (94.86˚C ) and heat flow (121.67 mW/m2) values among the other studied areas; the values that are in harmony with the average temperature (95˚C ) and heat flow (116 mW/m2) values obtained from the analysis of temperature data [8] [9] . The most common direct use are; district heating, aquaculture, agricultural applications, and swimming pools are already constructed along the eastern coastal parts of Gulf of Suez.
The geothermal resources of Egypt can be classified as three main types; low enthalpy geothermal resources which are located mainly in the Western desert of Egypt, around the Gulf of Suez and in some locations in Sinai. The second type is medium enthalpy geothermal resources represented by some hot springs and geothermal targets around Gulf of Suez. The third type is high enthalpy geothermal resources where geothermal anomalies encountered in the rift of depo-centres areas of the Gulf of Suez and Red Sea [8] [9] [10] [11] .
3. Binary Cycle Power Plant Configuration
To design a binary power plant, it is required to design its components which are preheater, evaporator, condenser, feed pump, turbine, generator and cooling tower. Figure 1 illustrates the desired binary cycle power plant scheme. The function of preheater is to provide a sufficient heat to raise the organic fluid to its boiling point. The evaporator is used for evaporating the boiled working fluid [12] [13] . The pressurized vapour steam of organic fluid expands in the turbine and leads to rotation of the rotor. The rotational kinetic energy is converted to electricity using the rotor connected to a generator. The thermal energy from the organic fluid is converted to electrical energy through the generator. The condenser condenses the working fluid vapor steam out from turbine due to the transfer of its heat to the cooling water for changing its phase to a liquid state before entering the feed pump [14] [15] .
Selection of Working Fluid
For binary power cycles design, the main challenges of the ORC are the choice of an appropriate working fluid. A common characteristic of all working fluids used in binary cycle power plant is their low boiling point [16] [17] . They also have critical temperatures and pressures lower than water. In order to give a representative review of the organic working fluids that can be used in a geothermal binary power plant, three hydrocarbons (Butane, Isobutane and Pentane) and one synthetic refrigerant (R245fa) are tested. The thermodynamic properties such as critical temperature, critical pressure, etc., of the working fluid strongly influence the performance of the system. These properties are not the only criteria to be taken into account during the selection of a working fluid; other key criteria include the impact of the working fluid on total system cost, health safety and environmental impacts [18] [19] . The thermodynamic, environmental and health properties of some of the working fluids considered best for low temperature reservoir binary plants are shown in Table 1 [2] .
4. Thermodynamic Modeling
The design of a geothermal binary plant needs to take into account the particular type of thermodynamic cycle, pump, turbine, heat exchanger, condenser, and
Figure 1. Configuration of geothermal binary cycle power plant.
Table 1. Thermodynamics health and environmental properties of some candidate working fluids.
1: ozone depletion potential; 2: global warming potential.
cooling system. The energy analysis based on the first and second laws of thermodynamics is evaluated for different organic working fluids under diverse working conditions. A thermodynamic model of the conceptual design is developed using MATLAB program. The thermodynamic heat balance is given as [20] :
(1)
(2)
where, h2 is the turbine input enthalpy, h1 is enthalpy of the working fluid, ηtur is the turbine efficiency, h2s is isentropic enthalpy of the working fluid after the turbine, h4 is the condenser outlet enthalpy, h5 is the enthalpy of organic fluid entering the evaporator (kJ/kg), h5s is the enthalpy of the working fluid assuming isentropic process, ηp is the pump efficiency. The outlet temperature of the cooling water is calculated from the inlet cooling temperature, which is increased by raising the temperature of the cooling water in the condenser as [20] :
(3)
where Tco is the outlet cooling temperature, Tci is the inlet cooling temperature and Tdelta is the increase of inlet water temperature in the condenser caused by heat transfer between the cooling water and the working fluid. Evaporator mass balance equation and Preheater mass balance equation are given by [21] [22] :
(4)
(5)
where
is the brine mass flow rate (kg/s), Cpb is the specific heat of brine (kJ/kg K), and
is the working fluid flow rate, Tb is the brine temperature, Tr is the reinjection temperature. h5 and h6 are the enthalpy of preheater and evaporator respectively. The relationship between the mass flow of the working fluid and the mass flow of the cooling water is given by mass balance equations. Cooling water mass flow is given by [21] :
(6)
where
is the cold water flow rate (kg/s), Cpw is the specific heat of cold water (kJ/kg K). The condenser is used to condensate the steam leaving the turbine. It exchanges the heat between the cooling fluid cycle and the working fluid vapour. Condensing temperature determination [21] :
(7)
where and Tcond is the temperature of condensation (K). Heat rejected from the working fluid to the cooling water in the condenser (Qc) is calculated using enthalpies of inlet and outlet parameters of the working fluid in the condenser [2] :
(8)
The output power of the plant can be calculated using the following equations [2] :
(9)
(10)
(11)
(12)
The power used by the fan to move air through the cooling system (Qt) is given by:
(13)
Electric power produced in the turbine, which is lowered by parasitic losses, is called net power. Net power is the total electric power produced by the power plant which can be sent to a network for use .Where Wnet is the net power output of power plant, Wt is the power produced by turbine, Wp is the power used by all pumps in cycle and Wf is the power used by cooling fans, pf is fan power, ηf is the efficiency of the fan motor, ṁg is geothermal flow rate. The system efficiency (ηnet) for an ORC system is defined as [19] :
(14)
The required area for the plant component can be calculated after the heat transfer for different component. Preheater area can be calculated according to [2] :
(15)
(16)
where Tb is the temperature of geothermal leaving the evaporator. Evaporator area can be calculated according to [2] :
(17)
Condenser area can be calculated according to [2] :
(18)
where U is the overall heat transfer coefficient (˚C/m2), A is the heat transfer area (m2), and LMTD is the Logarithmic Mean Temperature Difference (˚C ).
5. Results and Discussion
Bir Nabi in the Eastern desert, Egypt of temperature 92˚C is used as the well under test [22] . A sensitivity analysis of the binary cycle output power is presented for the variation of geothermal temperature, geothermal flow rate and reinjection temperature for the four alternative working fluids; Butane, Isobutane, Pentane and R245fa. These results are obtained on the basis of a constant ambient and condensation temperatures of 26˚C and 30˚C, respectively. To make the comparison meaningful, some parameters for heat source sink and power plant components have been selected as fixed values. Table 2 gives the initial condition and the assumptions for the plant design.
Table 3 shows the output power and efficiency for the selected four working fluids calculated at geothermal temperature of 92˚C, reinjection temperature of 70˚C and geothermal flow rate of 20 kg/s. It was found from Table 3 that, Pen-
Table 2. Assumptions for heat source sink and power plant component.
tane meets our demand, giving the highest output power of approximately 213 kW and the highest thermal efficiency of 11.5%. On the other hand, R245fa yielded the lowest power output and the lowest efficiency.
Figure 2 shows the variation of the net power output with geothermal temperature for the four working fluids at geothermal flow rate and reinjection temperature of 20 kg/s and 70˚C respectively. It is shown that, the output power of the cycle is directly proportional with the geothermal temperature. Output power is positively correlated with geothermal temperature as this temperature increases the plant output power increases for all fluids. Also the pentane produces the highest power while the R245fa produce the lowest output power and the output power of Butane, Isobutane and R245fa are closer to each other especially for low geothermal temperature.
Figure 3 shows the variation of power output over a reinjection temperature range of 30˚C to 70˚C for different working fluids. The analysis is carried out using geothermal temperature and geothermal flow rate of 90˚C and 20 kg/s, respectively. The reinjection temperature varies from 30˚C to 70˚C at keeping the other condition of the plant constant. For the different geofluid, it is clear that, the relation between output power and Tr is negative correlated.
Figure 4 illustrates the variation of power output with geothermal flow rate for the used working fluids over a geothermal flow rate of 10 - 50 kg/s at geothermal temperature and reinjection temperature of 90˚C and 70˚C, respectively. More mass flows into a plant results in a larger amount of heat that is available to be converted into work. The Pentane produces the highest power while the R245fa produces the lowest output power. The output power of Butane,
Figure 2. Variation of net power output with geothermal temperature for different working fluids.
Figure 3. Variation of net power output with reinjection temperature for different working fluids.
Figure 4. Variation of net power output with geothermal flow rate for different working fluids.
Isobutan and R245fa are very closer to each other especially for low geothermal flow rate.
The variation of evaporator, preheater and condenser area with variation of geothermal temperature are given in Figure 5, Figure 6 and Figure 7. This reveals that, the heat exchanger area will be increased with the increase of the amount of heat transfer rate. The surface areas of these components exponentially increase with increasing geothermal temperature as seen in these figures. The heat exchangers designed area in case of Pentane is smaller than in case of R245fa working fluid. The difference of the heat transfer areas occurs because these cycle designs need different heat duty of the heat exchangers. Each heat exchanger design has a different overall heat transfer coefficient and logarithmic mean temperature difference (LMTD), which are the main factors affecting the heat exchanger. Each one of the working fluids has different thermodynamic properties; different areas of heat exchangers, evaporator and condenser are required.
The variation in the working fluid flow rate with geothermal fluid temperature is indicated in Figure 8. When the geothermal fluid temperature increases the working fluid flow rate is increased and larger quantity of working fluid passes through the fixed evaporator area. This causes an increase in the exit temperature of the working fluid from the evaporator and thus an increase in the level of working enthalpy parameter.
Figure 9 illustrates the variation of working fluid flow rate with the reinjection temperature. This flow rate is reduced with increasing reinjection temperature due to the reduction of amount of heat transfer rate with increasing reinjection temperature according to the energy balance equations.
Figure 5. Evaporator area variations for different geothermal temperature.
Figure 6. Preheater area variations for different geothermal temperature.
Figure 7. Condenser area variations for different geothermal temperature.
Figure 8. Working fluids flow rate variations for different geothermal temperature.
The calculated area of condenser and evaporator at different reinjection temperature for the four working fluids are shown in Figure 10 and Figure 11, respectively. These figures indicate that, as the reinjection temperature increases the area is reduced due to the reduction of the amount of heat transfer rate through evaporator and condenser.
Figure 9. Working fluids flow rate variations for different reinjection temperature.
Figure 10. Condenser area variations for different reinjection temperature.
Figure 11. Evaporator area variations for different reinjection temperature.
Figure 12. Working fluid flow rate variations for different geothermal flow rate.
Figure 13. Condenser area variations for different geothermal flow rate.
Figure 14. Preheater area variations for different geothermal flow rate.
Figure 15. Evaporator area variations for different geothermal flow rate.
Figure 12 gives the variation of working fluid flow rate with geothermal flow rate variation. The variation of condenser, preheater and evaporator areas with the variation of geothermal flow rate are shown in Figure 13, Figure 14 and Figure 15, respectively. These figures reveal that, the area of these components increases with increasing the geothermal flow rates.
6. Conclusion
This paper proposed a design of ORC binary power plant for low temperature geothermal. The well under test is found in the Eastern desert of Egypt of temperature 92˚C. Four working fluids are used; one is a refergant R245fa and the others are hydrocarbons; Butane, Isobutane and Pentane. Among the four different fluids, Pentane has the best performance over the others. To evaluate the performance of ORC binary plant, a sensitivity analysis was done based on varying geothermal temperature, reinjection temperature and geothermal flow rate. These parameters were taking into consideration to study their effects on output power, net efficiency of the plant, and plant component design (preheater, evaporator and condenser area). Moreover, the effect of dependency of the flow rate of working fluid was studied on geothermal temperature and reinjection temperature. An increase in geothermal reservoir temperature and flow rate results in an increase of the total heat transfer rate and the produced output power and the efficiency of the plant. In contrast, an increase in reinjection temperature results in a decrease of the total heat transfer rate, the produced output power and the efficiency of the plant.